140
Date of issue: 07/30/2012
Proximity Sensors,
Inductive Sensors,
cylindrical
1
.1.1
Electrical Connection
For detailed data and product description refer to the data sheets at
Technical Data
Germany: +49 621 776-4411
Consider the General Notes on the Information in the Pepperl+Fuchs Product Catalogs
Pepperl+Fuchs Group
fa-info@de.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
Copyright Pepperl+Fuchs
D
L
Pos. A
Pos. B
Pos. C
lc
l1
lt
General Data
Switching element function
NAMUR, NC
Type of voltage
DC
Nominal voltage
8.2
V (R
i
approx. 1 k
)
Current consumption
Measuring plate not detected
3
mA
Measuring plate detected
1
mA
Ambient temperature
-40 ... 150
°C (-40 ... 302 °F)
Housing material
PPS
Protection degree
IP65
Connection type
cable SIHF , 2 m
Model Number
NJ5-18GK-N-150
NJ8-18GK-N-150
Rated operating distance
5
mm
●
8
mm
●
Installation
flush
●
non-flush
●
Switching frequency
0 ... 200
Hz
●
0 ... 500
Hz
●
Use in the Hazardous Area
Use in the hazardous area
see instruction manuals
●
●
Category
1
G; 2G
●
●
Approvals and Certificates
UL approval
cULus Listed, General Purpose
●
●
CSA approval
cCSAus Listed, General Purpose
●
●
CCC approval
Products with a maximum operating voltage of
36
V do not bear a CCC
marking because they do not require approval.
Dimensions
Length L [mm]
47
Diameter D [mm]
18
Thread length l
t
[
mm]
34.5
Cap length l
1
[
mm]
1
Connector area l
c
[
mm]
7
LED position
-
Inductive sensor
cylindrical, Ø 18 mm for high temperature
Ø18 mm housing
5
mm, flush and 8 mm, non-flush
mountable versions
DC, 2-wire NAMUR
Cable version
For use in high temperature appli-
cations
Ex approval for use in hazardous
area zone 0 and 1
Properties
Your Benefit
BN
L+
L-
BU
NJ5-18GK-N-150
NJ8-18GK-N-150
0102