For detailed data and product description refer to the data sheets at
Proximity Sensors,
Inductive Sensors,
cylindrical
1
.1.1
Technical Data
Electrical Connection
D
L
Pos. A
Pos. B
Pos. C
lc
l1
lt
General Data
Switching element function
NAMUR, NC
Nominal voltage
8.2
V (R
i
approx. 1 k
)
Current consumption
Measuring plate not detected
3
mA
Measuring plate detected
1
mA
Ambient temperature
-25 ... 100
°C (-13 ... 212 °F)
Connection type
cable PVC , 2 m
Model Number
NJ5-18GK-N
NJ8-18GK-N
NCB5-18GK40-N0
NCN8-18GK40-N0
Rated operating distance
5
mm
8
mm
Installation
flush
non-flush
Switching frequency
0 ... 200
Hz
0 ... 300
Hz
0 ... 400
Hz
0 ... 500
Hz
Indication of the switching state all direction LED, yellow
● ●
Housing material
PBT
● ●
PBT/PPS
● ●
Protection degree
IP66 / IP68
IP67
● ●
IP68
Use in the Hazardous Area
Use in the hazardous area
see instruction manuals
● ● ● ●
Category
2
G; 1D
● ● ● ●
Approvals and Certificates
Control drawing
116-0165
F
● ● ● ●
UL approval
cULus Listed, General Purpose
● ● ● ●
CSA approval
cCSAus Listed, General Purpose
● ● ● ●
CCC approval
Products with a maximum operating voltage of
36
V do not bear a CCC
marking because they do not require approval.
Dimensions
Length L [mm]
39
40
Diameter D [mm]
18
Thread length l
t
[
mm]
34.5
37
Cap length l
1
[
mm]
1
0
Connector area l
c
[
mm]
0
LED position
-
Pos. C
BF 18
Mounting flange, 18 mm
This and more accessories can be found in chapter 10
See pages from 974 ... for cordsets
See pages 1074 ... for mounting aids
Accessories
Inductive sensor
cylindrical, Ø 18 mm (NAMUR)
Ø18 mm housing
5
mm flush mountable and 8 mm
non-flush mountable versions
DC, NAMUR interface
Cable version
ATEX approved sensor applicable
up to zone 0 and zone 20
Usable up to SIL2 acc. to IEC 61508
Properties
Your Benefit
BN
L+
L-
BU
NCB5-18GK40-N0
NJ5-18GK-N
NCN8-18GK40-N0
NJ8-18GK-N
0102