Page 178 - SENSORS AND SYSTEMS | PEPPERL+FUCHS

176
Date of issue: 07/30/2012
Proximity Sensors,
Inductive Sensors,
rectangular types
1
.1.2
Electrical Connection
For detailed data and product description refer to the data sheets at
Technical Data
Germany: +49 621 776-4411
Consider the General Notes on the Information in the Pepperl+Fuchs Product Catalogs
Pepperl+Fuchs Group
fa-info@de.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
Copyright Pepperl+Fuchs
H
W
L
lc
General Data
Rated operating distance
4
mm
Installation
non-flush
Operating voltage
10 ... 30
V DC
No-load supply current
15
mA
Reverse polarity protection
Switching frequency
0 ... 500
Hz
Operating current
0 ... 100
mA
Short-circuit protection
pulsing
Indication of the switching state LED, yellow
Ambient temperature
-25 ... 70
°C (-13 ... 158 °F)
Housing material
PBT
Protection degree
IP67
Model Number
NBN4-V3-E0
NBN4-V3-E2
Switching element function NPN
NO
PNP
NO
Connection type
cable PVC , 100 mm
cable PVC , 130 mm
Approvals and Certificates
UL approval
cULus Listed, General Purpose
CSA approval
cCSAus Listed, General Purpose
CCC approval
Products with a maximum operating voltage of
36
V do not bear a CCC mar-
king because they do not require approval.
Dimensions
Length L [mm]
27.8
Width W [mm]
16
Height H [mm]
10
Connector area l
c
[
mm]
0
Inductive sensor
V3 series
Miniature V3 housing
4
mm, non-flush mountable
DC, 3-wire switching output
Cable version
Properties
BN
L+
L-
BK
BU
BN
L+
L-
BK
BU
NBN4-V3-E0
NBN4-V3-E2