General Data
Operating voltage
10 ... 30
V DC
No-load supply current
15
mA
Reverse polarity protection
✔
Operating current
0 ... 100
mA
Short-circuit protection
pulsing
Indication of the switching state LED, yellow
Ambient temperature
-25 ... 70
°C (-13 ... 158 °F)
Housing material
PBT
Protection degree
IP67
Connection type
cable PVC , 130 mm
Model Number
NBB2-V3-E2-3G-3D
NBB2-V3-E3-3G-3D
NBN4-V3-E2-3G-3D
Rated operating distance
2
mm
●
●
4
mm
●
Installation
flush
●
●
non-flush
●
Switching element function PNP
NO
●
●
PNP
NC
●
Switching frequency
0 ... 1000
Hz
●
●
0 ... 500
Hz
●
Use in the Hazardous Area
Use in the hazardous area
see instruction manuals
●
●
●
Category
3
G; 3D
●
●
●
Approvals and Certificates
UL approval
cULus Listed, General Purpose
●
●
●
CSA approval
cCSAus Listed, General Purpose
●
●
●
CCC approval
Products with a maximum operating voltage of
36
V do not bear a CCC mar-
king because they do not require approval.
Dimensions
Length L [mm]
27.8
Width W [mm]
16
Height H [mm]
10
Connector area l
c
[
mm]
0
Inductive sensor
V3 series (3G/3D)
Miniature V3 housing
2
mm, flush and 4 mm non-flush
mountable versions
DC, 3-wire switching output
Cable version
ATEX approval for use in zone 2/
zone 22
Properties
Your Benefit
BN
L+
L-
BK
BU
BN
L+
L-
BK
BU
NBB2-V3-E3-3G-3D
NBB2-V3-E2-3G-3D
NBN4-V3-E2-3G-3D