314
Date of issue: 08/06/2012
Proximity Sensors,
Capacitive Sensors,
rectangular types
1
.2.2
Electrical Connection
For detailed data and product description refer to the data sheets at
Technical Data
Germany: +49 621 776-4411
Consider the General Notes on the Information in the Pepperl+Fuchs Product Catalogs
Pepperl+Fuchs Group
fa-info@de.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
Copyright Pepperl+Fuchs
L
lc
W
H
General Data
Installation
non-flush
Switching element function
NAMUR, NO
Nominal voltage
8.2
V (R
i
approx. 1 k
)
Current consumption
Measuring plate not detected
1
mA
Measuring plate detected
2.2
mA
Switching frequency
0 ... 10
Hz
Ambient temperature
-25 ... 70
°C (-13 ... 158 °F)
Model Number
CBN2-F46-N1
CBN5-F46-N1
CBN10-F46-N1
CCN5-F46A-N1
CCN10-F46A-N1
Rated operating distance
10
mm
●
●
2
mm
●
5
mm
●
●
Housing material
PBT
● ● ●
PVDF
● ●
Protection degree
IP67
● ● ●
IP68
● ●
Connection type
cable FEP , 2 m
● ●
cable PUR , 2 m
● ● ●
Use in the Hazardous Area
Use in the hazardous area
see instruction manuals
● ● ● ● ●
Category
1
G; 2G; 1D
● ● ● ● ●
Approvals and Certificates
Control drawing
116-0165
F
● ●
● ●
UL approval
cULus Listed, General Pur-
pose
● ● ● ● ●
CSA approval
cCSAus Listed, General Pur-
pose
● ● ● ● ●
CCC approval
Products with a maximum operating voltage of
36
V do not bear a CCC
marking because they do not require approval.
Dimensions
Length L [mm]
22
20.4
Width W [mm]
50
42
Height H [mm]
5
10.5
Connector area l
c
[
mm]
3
10
Capacitive sensor
F46 / F46A series, NAMUR
Flat F46 / F46A housing
Up to 10 mm, non-flush mountable
versions
DC, NAMUR interface
Cable version
ATEX approved sensor applicable
up to zone 0 and zone 20
Soiling-repellent PTFE housing
versions (F46A)
Ready-for-use switching distance
Properties
Your Benefit
BN
L+
L-
BU
CBN10-F46-N1
CBN2-F46-N1
CBN5-F46-N1
CCN10-F46A-N1
CCN5-F46A-N1
0102