508
Date of issue: 2012-08-09
Photoelectric Sensors,
Standard Sensors,
thru-beam sensors
2
.1.4
Electrical Connection
For detailed data and product description refer to the data sheets at
Technical Data
Germany: +49 621 776-4411
Consider the General Notes on the Information in the Pepperl+Fuchs Product Catalogs
Pepperl+Fuchs Group
fa-info@de.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
Copyright Pepperl+Fuchs
❍
= light on,
●
= dark on
W
L
lc
H
Model Number
L36/LV36-Ex/40b/116
Sensitivity adjustment
✔
Light/dark switch
✔
Threshold detection range
30
m
Effective detection range
0 ... 30
m
Light source
LED , 660 nm
Light type
modulated visible red light
Operating voltage
6 ... 16
V DC (R
i
approx. 0 Ohm)
Switching type
light/dark on, programmable
Signal output
1
NAMUR output NC/NO programmable
Switching frequency
100
Hz
Current consumption
Emitter:
2.2
mA , Receiver:
Reference target detected
connection 1, 2:
2.2
mA
connection 1, 4:
1
mA
Reference target not detected
connection 1, 2:
1
mA
connection 1, 4:
2.2
mA
Ambient temperature
-25 ... 70
°C (-13 ... 158 °F)
Material
Housing
PMMA
Optical face
PMMA
Protection degree
IP54
Connection
terminal compartment PG9,
2.5
mm
2
Use in the Hazardous Area
Marking
¬
II 2G Ex op is ia IIC T4
Approvals and Certificates
CCC approval
Products with a maximum operating voltage of
36
V do not
bear a CCC marking because they do not require approval.
Dimensions
Length L [mm]
45.5
Width W [mm]
22
Height H [mm]
72
Connector area l
c
[
mm]
13.5
Thru-beam sensor, NAMUR
RL36 series
Emitter / receiver set
Rectangular full-size housing
Plastic housing
NAMUR output
Terminals version
Visible red light
ATEX-approval for zone 1
Intrinsically safe Ex op is ia IIC T4
Properties
Your Benefit
Option 40b
Receiver
Emitter
+UB
1
2
0
V
4
0
V
+UB
1
2
0
V
L36/LV36-Ex/40b/116