Page 514 - SENSORS AND SYSTEMS | PEPPERL+FUCHS

512
Date of issue: 2012-08-13
Photoelectric Sensors,
Standard Sensors,
fiber optic sensors
2
.1.6
Electrical Connection
For detailed data and product description refer to the data sheets at
Technical Data
Germany: +49 621 776-4411
Consider the General Notes on the Information in the Pepperl+Fuchs Product Catalogs
Pepperl+Fuchs Group
fa-info@de.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
Copyright Pepperl+Fuchs
= light on,
= dark on
H
L
W
lc
General Data
Sensor principle
Fiber optic sensor for glass fiber optics and plastic fiber optics
Sensor range
up to 150 mm (KLR-C02-2,2-2,0-K146)
Detection range
up to 450 mm (KLE-C01-2,2-2,0-K116)
Light type
modulated visible red light , 660 nm
Gang mounting
maximum 20 units / 100 mA load current per unity
Diagnostics display
7-
segment display
Operating voltage
10 ... 30
V DC
No-load supply current
30
mA
Switching type
light/dark on selectable programmable
Switching current
max. 100 mA , resistive load
Switching frequency
High speed mode: 16 kHz , Standard mode: 3 kHz , High resolution: 250 Hz ,
Automatic: 250 Hz ~ 3 kHz (selection by the sensor), Glass mode: 250 Hz
Timer function
ON-delay, OFF-delay, one shot, pulse extension ; adjustable 0 ... 999 ms in
1
ms increments
Ambient temperature
-10 ... 55
°C (14 ... 131 °F)
Housing
PC
Protection degree
IP50
Connection
2
m PVC cable, 4 x 0,14 mm
2
Model Number
SU19/102/115/123
SU19/102/115/126a
SU19/103/115/123
SU19/110/115/123
SU19/110/115/126a
Signal output
1
push-pull (4 in 1) output NPN/PNP , short-
circuit protected
● ●
1
NPN, short-circuit protected open collector
● ●
1
PNP, short-circuit protected, open collector
Output of the pre-fault indica-
tion
1
push-pull (4 in 1) output NPN/PNP , short-
circuit protected
1
NPN, short-circuit protected open collector
Function input
external Teach-In
● ●
Approvals and Certificates
UL approval
cULus Listed, Class 2 Power Source, Type 1
enclosure
● ● ● ● ●
CCC approval
Products with a maximum operating voltage of
36
V do not bear a CCC mar-
king because they do not require approval.
Dimensions
Length L [mm]
62,3
Width W [mm]
9
Height H [mm]
34,5
Connector area l
c
[
mm]
2
Bracket SU
Mounting bracket for DIN rail
This and more accessories can be found in chapter 10
See pages from 974 ... for cordsets
See pages 1074 ... for mounting aids
Accessories
Fiber optic sensor
SU19 series, master modules
Suitable for use with glass fiber op-
tics and plastic fiber optics
DIN rail housing
Plastic housing
Cable version
Visible red light
AGC (Automatic Gain Control) for
simple and time-saving teaching
High resolution four-digit percenta-
ge display for clear, unambiguous
indication of signal statuses
Properties
Your Benefit
Option 102/115/126a
Alarm
+UB
BN
WH
BU
0
V
BK
Q
+UB
BN
WH
BU
0
V
BK
Q
Option /103/115/123
Teach
+UB
BN
WH
BU
0
V
BK
Q
Option 102/115/123
Teach
+UB
BN
WH
BU
0
V
BK
Q
Option 110/115/126a
Alarm
Option 110/115/123
Teach
+UB
BN
WH
BU
0
V
BK
Q
SU19/102/115/126a
SU19/103/115/123
SU19/102/115/123
SU19/110/115/126a
SU19/110/115/123