648
Date of issue: 07/30/2012
Ultrasonic Sensors,
Diffuse Mode Sensors,
rectangular types
3
.1
Electrical Connection
For detailed data and product description refer to the data sheets at
Technical Data
Germany: +49 621 776-4411
Consider the General Notes on the Information in the Pepperl+Fuchs Product Catalogs
Pepperl+Fuchs Group
fa-info@de.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
Copyright Pepperl+Fuchs
W
L
H
l1
lc
General Data
Operating voltage
10 ... 30
V DC , ripple 10 %
SS
Rated operational current
200
mA , short-circuit/overload protected
Synchronization
bi-directional
Ambient temperature
-25 ... 70
°C (-13 ... 158 °F)
Material
Housing
ABS
Transducer
epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT
Protection degree
IP54
Connection type
Device connector M12 x 1 , 5-pin
Model Number
UB500-F42-E4-V15
UB500-F42-E5-V15
UB2000-F42-E4-V15
UB2000-F42-E5-V15
UB4000-F42-E4-V15
UB4000-F42-E5-V15
UB6000-F42-E4-V15
UB6000-F42-E5-V15
Sensing range
30 ... 500
mm
● ●
60 ... 2000
mm
● ●
200 ... 4000
mm
● ●
350 ... 6000
mm
● ●
Transducer frequency
approx. 390 kHz
● ●
approx. 175 kHz
● ●
approx. 85 kHz
● ●
approx. 65 kHz
● ●
No-load supply current
50
mA
● ● ● ●
60
mA
● ● ● ●
Output type
1
switch output E4, NPN, NO/NC, pro-
grammable
● ● ● ●
1
switch output E5, PNP NO/NC, pro-
grammable
● ● ● ●
Switching frequency
0.6
Hz
● ●
1.2
Hz
● ●
2.7
Hz
● ●
8
Hz
● ●
Approvals and Certificates
UL approval
cULus Listed, General Purpose
● ● ● ● ● ● ● ●
CSA approval
cCSAus Listed, General Purpose
● ● ● ● ● ● ● ●
Dimensions
Length L [mm]
80
Width W [mm]
80
Height H [mm]
34
Transducer length l
1
[
mm]
0
16
Connector area l
c
[
mm]
16
MH 04-3505
Mounting aid for FP sensors
MHW 11
Mounting brackets for sensors
V15-G-2M-PVC
Cable socket, M12, 5-pin, PVC cable
V15-W-2M-PUR
Cable socket, M12, 5-pin, PUR cable
This and more accessories can be found in chapter 3.5 from page 676
See pages from 974 ... for cordsets
See pages 1074 ... for mounting aids
Accessories
Ultrasonic sensor
F42 series
Up to 6000 mm sensing range ver-
sions
DC, switching output
Surface mount F42 housing, front
view
Connector version
Simple pushbutton configuration
Properties
Your Benefit
Standard symbol/Connections:
(
version E4, npn)
Switch output
Program input
Sync. input
Wire colors in accordance with EN 60947-5-2.
1
4
5
3
2
+ U
B
-
U
B
(
BN)
(
BK)
(
WH)
(
GY)
(
BU)
U
Standard symbol/Connections:
(
version E5, pnp)
Program input
Sync. input
Switch output
Wire colors in accordance with EN 60947-5-2.
+ U
B
1
-
U
B
2
4
3
5
(
BN)
(
WH)
(
GY)
(
BK)
(
BU)
U
UB500-F42-E4-V15
UB2000-F42-E4-V15
UB4000-F42-E4-V15
UB6000-F42-E4-V15
UB500-F42-E5-V15
UB2000-F42-E5-V15
UB4000-F42-E5-V15
UB6000-F42-E5-V15
1
3
4
5
2
1
BN
2
WH
3
BU
4
BK
5
GY
Wire colors in accordance with EN 60947-5-2
(
brown)
(
white)
(
blue)
(
black)
(
gray)