Page 805 - SENSORS AND SYSTEMS | PEPPERL+FUCHS

Germany: +49 621 776-4411
Consider the General Notes on the Information in the Pepperl+Fuchs Product Catalogs
Pepperl+Fuchs Group
fa-info@de.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
Copyright Pepperl+Fuchs
Date of issue: 30.07.2012
803
For detailed data and product description refer to the data sheets at
Positioning Systems,
Position Encoding System
WCS
5
.3
Technical Data
Electrical Connection
L
H
W
General Data
Operating voltage
24
V DC ± 20 %
Power consumption
2
W (without read heads)
Interface 1
Connection of
control system
Interface type
Push-pull, parallel
Transfer rate
max. 500 Updates/s
Output stage
Push-pull output
Interface 2
Connection of
Reading head
Connectable read heads WCS-LS211 , WCS-LS111
Interface type
RS 485
Transmission method half duplex
Transfer rate
max. 187.5 kBit/s
Refresh cycle of read
head
1
ms
Control input
store input
2
inputs for reading head address
Output type
PNP
Signal output
error condition
Rated operational current
15
mA
Operating temperature
0 ... 55
°C (32 ... 131 °F)
Protection degree
IP20
Load current
max. 5 mA
Connection type
removable terminal block
Model Number
WCS-IP110
WCS-IP111
WCS-IP120
WCS-IP121
Data output format
binary code
Gray code
RS485 termination resistor
integrated
● ●
without
● ●
Approvals and Certificates
CCC approval
Products with a maximum operating voltage of
36
V do not bear a CCC
marking because they do not require approval.
Dimensions
Length L [mm]
121
Width W [mm]
100
Height H [mm]
74
WCS interface module
WCS-IP1**
RS 485 to parallel interface
Connection of up to 4 read heads
LS211 or LS111
DIN rail mounting
Properties
Control
unit
(
e.g.PLC)
Reading
head
WCS.-LS221
WCS-IP**
GND
GND
SDB
SDA
SUB
UB+
Store, A00, A01
PE
PE
19
D0 - D18
ERR
UB+
WCS-IP110
WCS-IP111
WCS-IP120
WCS-IP121