For detailed data and product description refer to the data sheets at
Positioning Systems,
Data Matrix Positioning System
PCV
5
.4
Technical Data
Electrical Connection
L
H
lc
W
General Data
Measuring range
max. 10000 m
Resolution
± 0.1 mm
Operating voltage
15 ... 30
V DC , PELV
No-load supply current
max. 200 mA
Interface
Interface type
RS 485 interface
Data output code
binary code
Transfer rate
38400 ... 230400
Bit/s
Termination
Switchable terminal resistor
Input
Input type
1
to 3 functional inputs , programmable
Output
Output type
1
to 3 switch outputs , PNP , programmable , short-circuit protected
Switching current
150
mA each output
Operating temperature
0 ... 60
°C (32 ... 140 °F) , -20 ... 60 °C (-4 ... 140 °F) (noncondensing; pre-
vent icing on the lens!)
Housing
PC/ABS
Protection degree
IP67
Connection type
8-
pin, M12 x 1 connector
Model Number
PCV80-F200-R4-V19
PCV100-F200-R4-V19
Read distance
80
mm
100
mm
Depth of focus
± 15 mm
± 20 mm
Passage speed
12.5
m/s
8
m/s
Approvals and Certificates
UL approval
cULus Listed, General Purpose, Class 2 Power
Source
CCC approval
Products with a maximum operating voltage of
36
V do not bear a CCC mar-
king because they do not require approval.
Dimensions
Length L [mm]
51
Width W [mm]
70
Height H [mm]
70
Connector area l
c
[
mm]
14,5
PCV-USB-RS485-Converter Set
USB to RS 485 interface converter
PCV-KBL-V19-STR-RS485
Cable unit with power supply for USB / RS 485 interface converter
V19-G-ABG-PG9
Cable socket, M12, 8-pin, shielded, non pre-wired
V19-G-ABG-PG9-FE
Cable socket, M12, 8-pin, shielded, non pre-wired
PCV-SC12
Grounding clip for PCV system
This and more accessories can be found in chapter 10
See pages from 974 ... for cordsets
See pages 1074 ... for mounting aids
Accessories
Optical reading head
with RS 485 Interface
Data Matrix, 2 axis
10.000
meters measurement length
RS 485 interface
DC, pnp outputs
Configurable with PC and codecard
Small rectangular plastic housing
Simple assembly
Mechanically rugged
No wearing parts
Long operating life
Maintenance-free
Properties
Your Benefit
1
2
3
4
5
6
7
8
OUT 2 / IN 2
+ UB
Data +
Data -
OUT 1
IN 1
GND
OUT 3 / IN 3
1
4
6
7
8
5
3
2