807
For detailed data and product description refer to the data sheets at
Positioning Systems,
Data Matrix Positioning System
PCV
5
.4
Technical Data
Electrical Connection
L
H
lc
W
Model Number
PCV80-F200-B6-V15B
Read distance
80
mm
Measuring range
max. 10000 m
Resolution
± 0.1 mm
Depth of focus
± 15 mm
Passage speed
12.5
m/s
Operating voltage
15 ... 30
V DC , PELV
No-load supply current
max. 400 mA
Interface 1
Interface type
PROFIBUS DP V0
Protocol
PROFIBUS DP acc. to EN 50170
Transfer rate
9.6; 19.2; 93.75; 187.5; 500; 1500
kBit/s
3; 6; 12
Mbit/s self-synchronizing
Interface 2
Interface type
USB (serial comport)
Protocol
8
E1
Transfer rate
38.4 ... 460.8
kBit/s
Input
Input type
1
to 3 functional inputs , programmable
Output
Output type
1
to 3 switch outputs , PNP , programmable , short-circuit pro-
tected
Switching current
150
mA each output
Operating temperature
0 ... 60
°C (32 ... 140 °F) , -20 ... 60 °C (-4 ... 140 °F) (noncon-
densing; prevent icing on the lens!)
Housing
PC/ABS
Protection degree
IP67
Connection type
8-
pin, M12x1 connector, standard (supply+IO)
M12x1 socket, 5-pin, B-coded (Bus Out)
5-
pin, M12x1 connector, B-coded (Bus In)
Approvals and Certificates
UL approval
cULus Listed, General Purpose, Class 2 Power Source
CCC approval
Products with a maximum operating voltage of
36
V do not
bear a CCC marking because they do not require approval.
Dimensions
Length L [mm]
51
Width W [mm]
70
Height H [mm]
70
Connector area l
c
[
mm]
14.5
PCV-KBL-V19-STR-USB
USB cable unit with power supply
ICZ-TR-V15B
Terminal resistor for PROFIBUS
V15B-G-2M-PUR ABG-V15B-G
Bus cable PROFIBUS, M12 to M12, PUR cable
V15B-G-5M-PUR ABG-V15B-G
Bus cable PROFIBUS, M12 to M12, PUR cable
PCV-SC12
Grounding clip for PCV system
This and more accessories can be found in chapter 10
See pages from 974 ... for cordsets
See pages 1074 ... for mounting aids
Accessories
Optical reading head
with PROFIBUS
Data Matrix, 2 axis
10.000
meters measurement length
PROFIBUS interface
DC, pnp outputs
PLC configurable via fieldbus
Configurable with PC and codecard
Small rectangular plastic housing
Simple assembly
Mechanically rugged
No wearing parts
Long operating life
Maintenance-free
Properties
Your Benefit
1
2
3
4
5
1
2
3
4
5
6
7
8
1
2
3
4
5
OUT 2 / IN 2
+ UB
USB_DM
USB_DP
OUT 1
IN 1
GND
OUT 3 / IN 3
5
V ISO
BUS-A
BUS-GND ISO
BUS-B
SHIELD
Bus out
n.c.
BUS-A
n.c.
BUS-B
SHIELD
Bus in
Main
1
4
6
7
8
5
3
2
1
5
3
2
4
Bus out
1
5
3
4
2
Bus in
Main
R