870
Date of issue: 0801/2012
AS-Interface,
Safety at Work
7
.3
For detailed data and product description refer to the data sheets at
Technical Data
Germany: +49 621 776-4411
Subject to modifications without notice
Pepperl+Fuchs Group
fa-info@pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
Copyright Pepperl+Fuchs
General Data
Slave type
Safety-Slave
AS-Interface specification
V2.1
Required master specification
V2.0
UL File Number
E198304
MTTF
d
200
a
B
10
d
1
E+5
Inputs
Number/Type
2
NC
Safety function with positive opening operation
in accordance with IEC/EN 60947-5-1
Reset by pulling/turning
Supply
from AS-Interface
Functional safety
EN 954-1:1996, EN 62061:2005, EN 61508 Parts 1-7:1998-2000,
NFPA 79:2002, EN 60204-1:2006
Model Number
VAA-2E-F85A-S-V1
VAA-2E1A-F85A-S-V1
VAA-2E-PM-S
VAA-2E1A-PM-S
Rated operational current
25
mA
●
●
40
mA
●
●
Outputs
Number/Type
LED red
●
●
Supply
from AS-Interface
●
●
Profile
S-0.B.E
●
●
S-7.B.E
●
●
Ambient temperature
-25 ... 50
°C (-13 ... 122 °F) (no freezing)
●
-25 ... 55
°C (-13 ... 131 °F) (no freezing)
●
● ●
Protection degree
IP65
● ●
IP65
Module: IP20
● ●
Mechanical data
Panel mount
● ●
Surface mount
● ●
AS-Interface EMERGENCY STOP button
Emergency stop
Release of emergency stop by pull
or turn
IP65
AS-Interface intelligent E-stop with
M12 quick disconnect results in
fast error-free installation
Pull and twist release satisfies
customers preferences
Pre-tensioned mechanical design
results in secure deactivation of
contacts upon mechanical failure
Properties
Your Benefit
SAFETYATWORK