Page 954 - SENSORS AND SYSTEMS | PEPPERL+FUCHS

952
Date of issue: 07/31/2012
9
.1
Electrical Connection
For detailed data and product description refer to the data sheets at
Technical Data
Germany: +49 621 776-4411
Consider the General Notes on the Information in the Pepperl+Fuchs Product Catalogs
Pepperl+Fuchs Group
fa-info@de.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
Copyright Pepperl+Fuchs
General Data
Type
7-
segment LED display, red
Number of digits
6
Reset
manually or external
Storage temperature
-25 ... 70
°C (-13 ... 158 °F)
Relative humidity
80 % (
noncondensing)
Mounting
latch fastener
Model Number
KCT-6S-C
KCT-6ST-C
KCT1-6ST-V
KCT2-6ST-V
Function
Counter
● ● ● ●
Timer
Tachometer
Display value
digit height 14 mm
digit height 8 mm
● ● ●
Operating voltage
10 ... 30
V
DC
● ●
90 ... 250
V
AC
● ●
Power consumption
max. 6 VA
max. 7 VA
1.5
W
● ●
Counting frequency
20
kHz
30
Hz / 20 kHz
● ●
30
Hz / 20 kHz (max. 11 kHz when counting
with phase discriminator)
Output type
Transistor switching output
● ● ●
Sensor supply
● ●
Ambient temperature
-10 ... 50
°C (14 ... 122 °F)
● ● ●
-20 ... 65
°C (-4 ... 149 °F)
Connection
7-
pin screw terminal ,
max. core cross-section 0.34 ... 1.5 mm
2
2
plug-in 7-pin screw terminals
max. core cross-section 0.34 ... 1.5 mm
2
2-
pin and 7-pin plug-in connection terminals,
core cross-section
1.5
mm
2
5-
pin screw terminal ,
max. core cross-section 0.34 ... 1.5 mm
2
Mass
approx. 150 g
approx. 200 g
48
g
● ●
Dimensions
48
mm x 24 mm x 65 mm
● ●
48
mm x 48 mm x 106 mm
96
mm x 48 mm x 90 mm
Counters
LED Counter and LED Counter/Ti-
mer/Tachometer versions
10 - 30
V
DC
and 90 - 250 V
AC
supply
voltage versions
6
digits
Properties
Connection assignment X2
Terminal
No.
1
2
AC version
Power supply
90 ...260
V AC
Power supply
90 ...260
V AC
Terminal
No.
1
2
3
4
5
6
7
AC version
Optocoupler collector output
Optocoupler emitter output
SET
INP B
INP A
GND
+24V out
Connection assignment X1
21 3 4 5 6 7
21
X2
X1
4
5
3
2
6
7
1
Input B
Reset
Input A
10 ...30
V DC
GND
Counting device
with display
Polarity control
Optocoupler output
(
only KCT-6ST-C)
Connector assignment X1
supply voltage and outputs
Terminal
No.
1
2
3
4
5
6
7
AC version
Optocoupler output 1 collector
Optocoupler output 1 emitter
Optocoupler output 2 emitter
n.c.
Optocoupler output 2 collector
supply voltage
90 ...250
V AC
supply voltage
90 ...250
V AC
10 ...30
V
DC version
operating voltage
10 ...30
V DC
0
V DC (GND)
Terminal
No.
1
2
3
4
5
6
7
AC version
Sensor
Supply voltage
Reference voltage
Counter input A
Counter input B
Reset input
Gate circuit
Input for key locking
10 ...30
V
DC version
n.c.
n.c.
Name
+24VDC
0
VDC
(
GND)
INP A
INP B
RESET
GATE
KEY
Connector assignment X2
inputs
3
7
1
4 5 6
2
3
7
1
4 5 6
2
X2
X1
KCT2-6ST-V
KCT-6S-C
KCT-6ST-C
KCT1-6ST-V