208
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
Proximity Sensors,
Inductive Sensors,
cylindrical
1
.1.1
Technical Data
For detailed data and product description refer to the data sheets at
Electrical Connection
D
L
Pos. A
Pos. B
Pos. C
lc
l1
lt
General Data
Output type
NAMUR, NC
Type of voltage
DC
Nominal voltage
8.2 V (R
i
approx. 1 k
)
Current consumption
Measuring plate not detected
3 mA
Measuring plate detected
1 mA
Protection degree
IP65
Model Number
NJ4-30GM-N-200
NJ15-30GK-N-150
Rated operating distance
15 mm
4 mm
Installation
flush
non-flush
Switching frequency
0 ... 100 Hz
0 ... 1000 Hz
Suitable for 2:1 technology
Ambient temperature
-25 ... 150 °C (-13 ... 302 °F)
0 ... 200 °C (32 ... 392 °F)
Housing material
Stainless steel 1.4305 / AISI 303
PPS
Connection type
cable SIHF , 2 m
cable SIHF , 5 m
Use in the Hazardous Area
Use in the hazardous area
see instruction manuals
Category
1G; 2G
Approvals and Certificates
FM Control drawing
116-0165F
UL approval
cULus Listed, General Purpose
CSA approval
cCSAus Listed, General Purpose
CCC approval
CCC approval / marking not required for sensors rated
36 V
Dimensions
Length L [mm]
75
47
Diameter D [mm]
M30 x 1.5
Thread length l
t
[mm]
50
40
Cap length l
1
[mm]
0
Connector length l
c
[mm]
15
7
LED position
-
KCD2-SR-Ex2
2-channel isolated amplifier
For detailed information on isolated amplifiers refer to the data sheets at
These and more accessories can be found in chapter 10
See pages from 970 ... for cordsets See pages 1066 ... for mounting accessories
Accessories
Inductive sensor
cylindrical, Ø 30 mm for high temperature
Application Note:
Reference appendix, data sheet, operating
instructions, and appropriate standards.
To be used within the electrical, environmental, and
mechanical limitations of the device and area.
Ø30 mm housing
4 mm and 15 mm sensing ranges
NAMUR output
Cable version
For use in high temperature
applications
Ex approval for use in hazardous
area zone 0 and 1
Intrinsically safe when connected
to approved device
FM Class and Division approvals
Properties
Benefits
BN
L+
L-
BU
NJ15-30GK-N-150
NJ4-30GM-N-200
0102