274
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
Proximity Sensors,
Inductive Sensors,
rectangular types
1
.1.2
Technical Data
For detailed data and product description refer to the data sheets at
Electrical Connection
S
Flexible limit switch style housing
Up to 30 mm sensing ranges
AC, 2-wire switching output
Terminals
High Temperature models
Properties
Benefits
Wh
L
H
lc
W
General Data
Output type
AC
NO/NC
Operating voltage
20 ... 253 V AC
Switching frequency
0 ... 20 Hz
Load current
8 ... 500 mA
Operating voltage display
LED, green
Switching state indication
LED, yellow
Protection degree
IP68
Connection type
screw terminals
Model Number
NJ15+U2+W
NJ15+U4+W
NJ15+U4+W-T
NJ20+U2+W
NJ20+U4+W
NJ20+U4+W-T
NJ30+U2+W
NJ30+U4+W
NJ40+U2+W
NJ40+U4+W
NJ40+U4+W-T
Rated operating distance
15 mm
● ● ●
20 mm
● ● ●
30 mm
● ●
40 mm
● ● ●
Installation
flush
● ●
non-flush
● ● ● ● ● ● ● ● ●
Ambient temperature
-25 ... 100 °C (-13 ... 212 °F)
● ●
-25 ... 70 °C (-13 ... 158 °F)
● ● ● ● ● ● ● ●
0 ... 100 °C (32 ... 212 °F)
Material
PBT housing/plastic base
● ● ● ●
PBT housing/metal base
● ● ● ● ● ● ●
Approvals and Certificates
UL approval
cULus Listed, General Purpose
● ● ● ● ● ● ● ● ● ● ●
CSA approval
cCSAus Listed, General Purpose
● ● ● ● ● ● ● ● ● ● ●
CCC approval
Certified by China Compulsory Certification
(CCC)
● ● ● ● ● ● ● ●
Dimensions
Length L [mm]
118
128
Width W [mm]
40
Head width W
h
[mm]
40
55
Height H [mm]
40
55
Connector length l
c
[mm]
0
Connector thread
conduit entrance with
1/2" NPT opening
MHW 01
Modular mounting bracket
1/2"NPT-V12-G-S-.3M
Receptacle
1/2"NPT to
1/2’’ - 20 UNF, 3-pin
1/2"NPT-V93-G-S-.3M
Receptacle
1/2"NPT to
7/8’’ - 16 UN, 3-pin
These and more accessories can be found in chapter 10
See pages from 970 ... for cordsets See pages 1066 ... for mounting accessories
Accessories
1
L
3
2 4
N
1
L
3
2 4
N
NJ40+U2+W
NJ30+U2+W
NJ15+U2+W
NJ20+U2+W
NJ20+U4+W
NJ40+U4+W
NJ40+U4+W-T
NJ20+U4+W-T
NJ30+U4+W
NJ15+U4+W
NJ15+U4+W-T
Note: Only connect as Normally open or Normally closed - cannot be used simultaneously
Inductive sensor
AC, Limit switch style
1...,266,267,268,269,270,271,272,273,274,275 277,278,279,280,281,282,283,284,285,286,...1124