493
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
Photoelectric Sensors,
Standard Sensors,
Diffuse mode sensors with background suppression
2
.1
Technical Data
For detailed data and product description refer to the data sheets at
Electrical Connection
= light on,
= dark on
L
H
lc
W
Model Number
MLV41-8-HV-60-IR/110/124/167
Foreground suppression
Background suppression
Weak signal output
Test input
Foreground suppression
0 ... 15 mm
Background suppression
starts from 70 mm
Detection range
20 ... 60 mm fixed
Light type
modulated infrared light , 880 nm
Diameter of the light spot
max. 6 mm at a distance of 70 mm
Operating voltage
10 ... 30 V DC
No-load supply current
max. 25 mA
Signal output
1 push-pull output, short-circuit protected, reverse polarity protected
Switching current
max. 100 mA
Switching frequency
250 Hz
Weak signal output
1 push-pull output, short-circuit protected, reverse polarity protected
Test input
emitter deactivation at +U
B
Ambient temperature
0 ... 70 °C (32 ... 158 °F)
Material
Housing
aluminum , Delta-Seal coated
Optical face
glass pane
Protection degree
IP67
Connection
M12 x 1 connector, 5-pin
Approvals and Certificates
Protection class
II
UL approval
cULus Listed 57M3 (Only in association with UL Class 2 power
supply; Type 1 enclosure)
CCC approval
CCC approval / marking not required for sensors rated
36 V
Dimensions
Length L [mm]
31
Width W [mm]
13.6
Height H [mm]
56.5
Connector length l
c
[mm]
16
OMH-MLV41-8-HV-L
Mounting bracket
OMH-MLV41-8-HV-U
Mounting bracket
OMH-40
Mounting bracket
OMH-09
Mounting bracket for Sensors series MLV41 for M12 rod mounting
These and more accessories can be found in chapter 10
See pages from 970 ... for cordsets See pages 1066 ... for mounting accessories
Accessories
Foreground and background suppression sensor
MLV41 series
Foreground and background
suppression
Rectangular compact housing
Aluminum with Delta
®
-Seal
coating housing
DC sensor
Discrete output
Connector version
Infrared light
Special version for web-break
monitoring
Reliable detection of printed
materials of any kind
Extremely sharp background
suppression
Antistatic optical face inhibits dust
in paper and printing applications
Corrosion resistant Delta-Seal
housing
Patented design monitors lens
contamination
Properties
Benefits
Emitter
deactivation
activewhen
notsoiled
activewhen
soiled
Paper
web
Alarm
+UB
-UB
Test
1
2
3
4
5
Q2
Q1