691
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
Ultrasonic Sensors,
Diffuse Mode Sensors,
rectangular types
3
.1
Technical Data
For detailed data and product description refer to the data sheets at
Electrical Connection
W
L
H
lc
General Data
Operating voltage
20 ... 30 V DC , ripple 10 %
SS
No-load supply current
60 mA
Interface type
RS 232, 9600 bit/s, no parity, 8 data bits, 1 stop bit (S10 = OFF)
Rated operational current
200 mA , short-circuit/overload protected
Resolution
0.172 mm
Deviation of the characteristic
curve
0.2 % of full-scale value
Synchronization
1 synchronous connection, bidirectional
0-level: -U
B
... (-U
B
+ 1 V), 1-level: (-U
B
+ 5 V) ... +U
B
Ambient temperature
-25 ... 70 °C (-13 ... 158 °F)
Material
Housing
PBT
Transducer
epoxy resin/hollow glass sphere mixture; polyurethane foam
Protection degree
IP65
Connection
terminal compartment,
2.5 mm
2
conductor csa
Model Number
UC500+U9+IUE2+R2
UC3000+U9+IUE0+R2
UC3000+U9+IUE2+R2
Sensing range
60 ... 500 mm
300 ... 3000 mm
Transducer frequency
approx. 380 kHz
approx. 130 kHz
Output type
1 switch output E0, NPN, NO/NC
switchable
1 analog output, load-dependent:
R
L
500 Ohm: current output 4 ... 20 mA
R
L
1 kOhm: voltage output 2 ... 10 V
1 switch output E5: PNP NO/NC
switchable
1 analog output, load-dependent:
R
L
500 Ohm: current output 4 ... 20 mA
R
L
1 kOhm: voltage output 2 ... 10 V
Approvals and Certificates
UL approval
cULus Listed, General Purpose
CSA approval
cCSAus Listed, General Purpose
Dimensions
Length L [mm]
131
Width W [mm]
40
Height H [mm]
40
Connector length l
c
[mm]
0 ( M20 x 1.5 )
MH 04-2681F
Mounting aid for +U1+ and +U9* sensors
ULTRA3000
Software for ultrasonic sensors, UC line
UC-FP/U9-R2
Interface cable
These and more accessories can be found in chapter 3.4 from page 727
See pages from 970 ... for cordsets
See pages 1066 ... for mounting accessories
Accessories
Ultrasonic sensor
Limit Switch Style
500 and 3000 mm sensing ranges
DC, analog output, switching
output and RS 232 serial interface
Flexible limit switch housing
Terminal compartment
5-way sensing head
Software or DIP switch-based
configuration
Properties
Benefits
Sync. Input
E2 Output,TD
IU Output, RD
Standard symbol/Connection:
(Version IUE2, pnp)
1
2
4
3
5
+ U
B
- U
B
U
Sync. Input
E0 Output,TD
IU Output, RD
Standard symbol/Connection:
(Version IUE0, npn)
1
2
4
3
5
+ U
B
- U
B
U
UC500+U9+IUE2+R2
UC3000+U9+IUE2+R2