714
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
3
.3
Ultrasonic Sensors,
Speciality Models,
cylindrical
Technical Data
For detailed data and product description refer to the data sheets at
Electrical Connection
UC500-...-HA
UC2000-...-HB
UC4000-...-HA
Application Note:
Reference appendix, data sheet,
operating instructions, and appropriate standards.
To be used within the electrical, environmental, and
mechanical limitations of the device and area.
Ø30 mm stainless steel housing
with 1/2‘‘ NPT adapter
Up to 4000 mm sensing range
Analog output
M12 pigtailed quick disconnect
Designed for Hazardous Location
installation
Series HA: UL and CSA NRTL
certified for use in Class1, Div 2
environments
Series HB: UL and CSA NRTL
certified for use in all Div 2, as well
as Class II Div 1 and Class III Div 1
environments
Properties
Benefits
D1
D
1/2” NPT
l1
L
General Data
Operating voltage
10 ... 30 V DC , ripple 10 %
SS
Interface type
RS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit
Output type
1 current output 4 ... 20 mA
1 voltage output 0 ... 10 V
Deviation of the characteristic
curve
0.2 % of full-scale value
Ambient temperature
-25 ... 70 °C (-13 ... 158 °F)
Material
Housing
1.4303 stainless steel
plastic parts PBT
Transducer
epoxy resin/hollow glass sphere mixture; polyurethane foam
Protection degree
IP65
Connection type
Cable connector, M12 x 1, 5-pin, 4-wires
Model Number
UC500-30GM-IU-V1-HA
UC2000-30GM-IU-V1-HB
UC4000-30GM-IU-V1-HA
Sensing range
200 ... 4000 mm
30 ... 500 mm
80 ... 2000 mm
Transducer frequency
approx. 180 kHz
approx. 380 kHz
approx. 85 kHz
Resolution
evaluation range [mm]/4000, but
0.05 mm
evaluation range [mm]/4000, but
0.35 mm
Individual components
UC-500-30GM-IUR2-V15
V1-G-2M-PVC
ADAPT-ALUM*-M30X1/2" NPT/HB****
UC-2000-30GM-IUR2-V15
V1-G-2M-PVC
M-106 impact adapter
ADAPT-ALUM*-M30X1/2" NPT/HB****
UC-4000-30GM-IUR2-V15
V1-G-2M-PVC
ADAPT-ALUM*-M30X1/2" NPT/HB****
Approvals and Certificates
UL approval
all Div 2 hazardous areas
Class I Div 2 hazardous areas
Dimensions
Total length L [mm]
184
172
175
Head diameter D [mm]
30
42
40
Sensor length L
1
[mm]
79
68
71
Tube diameter D [mm]
35
UC-30GM-PROG
Interface extension cable
ULTRA3000
Programming software for UC-series ultrasonic sensors
UC-30GM-R2
Interface cable
These and more accessories can be found in chapter 3.4 from page 727
See pages from 970 ... for cordsets
See pages 1066 ... for mounting accessories
Accessories
Standard symbol/Connection:
(version IU)
Core colours in accordance with EN 60947-5-2.
+ U
B
- U
B
1
4
2
3
(BN)
(BK)
(WH)
(BU)
U
0-10V
4-20 mA
UC500-30GM-IU-V1-HA
UC4000-30GM-IU-V1-HA
UC2000-30GM-IU-V1-HB
Ultrasonic sensor - Hazardous Location
cylindrical, Ø 30 mm
1...,706,707,708,709,710,711,712,713,714,715 717,718,719,720,721,722,723,724,725,726,...1124