894
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
AS-Interface,
Modules
7
.4
Technical Data
For detailed data and product description refer to the data sheets at
Model Number
VBA-1E3A-M18-ZE/E2-V1
VAA-4E2A-G5-N/V2-Ex
VBA-4E-G16-ZEJ
VBA-4E4A-G16-ZEJ/E2L
Slave type
A/B slave
● ●
Standard slave
Required master specification
V2.0
V2.1
V3.0
UL File Number
E87056
● ●
Rated operating current
30 mA
40 mA (without sensors) / max. 240 mA
● ●
90 mA
Inputs
Number/Type
1 Input
4 inputs PNP
● ●
4 NAMUR inputs
Supply
from AS-Interface
● ●
from auxiliary power U
AUX
Voltage
21 ... 31 V
● ●
Current loading capacity
200 mA (T
B
40 °C),
150 mA (T
B
70 °C), overload-proof
and short-circuit protected
● ●
Input current
9 mA (limited internally)
● ●
Outputs
Number/Type
2 outputs for safe valves
3 electronic outputs, PNP
4 electronic outputs, PNP
Supply
from external auxiliary power U
AUX
Current
1 A per output
20 mA per output
Voltage
(U
AUX
- 0.5 V)
Profile
S-0.A.0
S-7.A.7
S-7.F
S-9.A.E
Ambient temperature
0 ... 70 °C (32 ... 158 °F)
-20 ... 60 °C (-4 ... 140 °F)
-25 ... 70 °C (-13 ... 158 °F)
● ●
Protection degree
IP54
IP67 / IP68 / IP69k
● ●
IP67
Mounting
screw mounting
● ● ●
VBP-HH1-V3.0-KIT-110V
AS-Interface Handheld with accessory
VBP-HH1-V3.0-110V
AS-Interface Handheld
VAZ-2T8-G11-*
Splitter box AS-Interface and auxiliary power to 8 x M12 round connector
VAZ-RK-PUR 2x1,5-YE 100M
AS-Interface round cable
VAZ-T1-FK-G10-*M-PUR-V1-G
Splitter box AS-Interface to 1x M12 round connector
VAZ-2T1-FK-G10-*M-PUR-V1-W
Splitter box AS-Interface and auxiliary power to 1 x M12 round connector
VAZ-V3-B
Blind plug for M8 sockets
These and more accessories can be found in chapter 7.6 from page 905
See pages from 970 ... for cordsets
See pages 1066 ... for mounting accessories
Accessories
AS-Interface sensor/actuator modules
Versions with 1 and 4 inputs /
versions with 2 outputs for safe
valves, 3 and 4 electronic outputs
Standard and A/B slave versions
IP54, IP67 and IP67/68/69k versions
VBA-1E3A-M18-ZE/E2-V1
Motor starter module designed to
simplify MOVIMOT control
VAA-4E2A-G5-N/V2-Ex
Approved for hazardous
environments up to Zone 1,
extends
AS-Interface advantages to critical
process control applications
VBA-4E*-G16-ZEJ*
M8 input/output connections are
advantageous when mounting
space is limited
M12 AS-Interface/AUX power
connection and lightweight
construction is ideal for robotics
applications
Output overload indication on
affected M12 port takes guessing
out of troubleshooting
Properties
Benefits