Version: V1.02.001Release Date: 2018-09-15


Reflex-Lichtschranke
Vendor ID 1 (0x0001) Vendor Logo
Vendor Name Pepperl+Fuchs
Vendor Text Pepperl+Fuchs
Vendor URL http://www.pepperl-fuchs.com
Device ID 1050112 (0x100600)
Communication
IO-Link Revision V1.0
Transmission Rate38400 bit/s (COM2)
Minimum Cycle Time 2.3 ms
SIO Mode Supported yes
Device Variant MLV41-6-IO/98/103
Description Reflex-Lichtschranke
Product ID 221590
Device Icon Device Icon
Device Symbol Device Symbol
Device Variant MLV41-6-IO/92/136
Description Reflex-Lichtschranke
Product ID 221591
Device Icon Device Icon
Device Symbol Device Symbol
Device Variant MLV41-6-IO/95/136
Description Reflex-Lichtschranke
Product ID 221592
Device Icon Device Icon
Device Symbol Device Symbol

ProcessData id=PD_ProcessData1 (condition V_OMC.2 == 0)

ProcessDataIn "Schaltsignale" id=PD_ProcessDataIn1

bit length: 2
data type: 2-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Inaktiv, true = Aktiv Schaltsignal - Bit 0
2 1 Boolean false = Funktionsreserve Alarm, true = Stabiler Betrieb Funktionsreserve - Bit 1
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex             2 1

ProcessData id=PD_ProcessData2 (condition V_OMC.2 == 1)

ProcessDataIn "Schaltsignale" id=PD_ProcessDataIn2

bit length: 2
data type: 2-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Inaktiv, true = Aktiv Schaltsignal - Bit 0
2 1 Boolean false = Stabiler Betrieb, true = Funktionsreserve Alarm Funktionsreserve - Bit 1
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex             2 1

Standard Variable "Direkte Parameter 1" index=0 id=V_DirectParameters_1

data type: 128-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger Reserviert
2 112 8-bit UInteger Master Zykluszeit
3 104 8-bit UInteger Minimale Zykluszeit
4 96 8-bit UInteger Telegramm-Fähigkeit
5 88 8-bit UInteger 16 IO-Link Versions-ID
6 80 8-bit UInteger Prozessdatenlänge Eingang
7 72 8-bit UInteger Prozessdatenlänge Ausgang
8 64 8-bit UInteger Hersteller-ID 1
9 56 8-bit UInteger Hersteller-ID 2
10 48 8-bit UInteger Geräte-ID 1
11 40 8-bit UInteger Geräte-ID 2
12 32 8-bit UInteger Geräte-ID 3
13 24 8-bit UInteger Reserviert
14 16 8-bit UInteger Reserviert
15 8 8-bit UInteger Reserviert
16 0 8-bit UInteger Reserviert

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "Direkte Parameter 2" index=1 id=V_DirectParameters_2

data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger Gerätespezifischer Parameter 1
2 112 8-bit UInteger Gerätespezifischer Parameter 2
3 104 8-bit UInteger Gerätespezifischer Parameter 3
4 96 8-bit UInteger Gerätespezifischer Parameter 4
5 88 8-bit UInteger Gerätespezifischer Parameter 5
6 80 8-bit UInteger Gerätespezifischer Parameter 6
7 72 8-bit UInteger Gerätespezifischer Parameter 7
8 64 8-bit UInteger Gerätespezifischer Parameter 8
9 56 8-bit UInteger Gerätespezifischer Parameter 9
10 48 8-bit UInteger Gerätespezifischer Parameter 10
11 40 8-bit UInteger Gerätespezifischer Parameter 11
12 32 8-bit UInteger Gerätespezifischer Parameter 12
13 24 8-bit UInteger Offsetzeit
14 16 8-bit UInteger Reserviert
15 8 8-bit UInteger Reserviert
16 0 8-bit UInteger Reserviert

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "Systemkommando" index=2 id=V_SystemCommand

data type: 8-bit UInteger
allowed values: 130 = Auslieferungszustand wiederherstellen
access rights: wo

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Herstellername" index=16 id=V_VendorName

data type: 64-octet String UTF-8
default value: "Pepperl+Fuchs GmbH"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Herstellertext" index=17 id=V_VendorText

data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Produktname" index=18 id=V_ProductName

data type: 64-octet String UTF-8
default value: "MLV41-6 - IO-Link"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Produkt-ID" index=19 id=V_ProductID

data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Produkttext" index=20 id=V_ProductText

data type: 64-octet String UTF-8
default value: "Retro Reflective Sensor"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Seriennummer" index=21 id=V_SerialNumber

data type: 16-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Hardwareversion" index=22 id=V_HardwareRevision

data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Firmwareversion" index=23 id=V_FirmwareRevision

data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Anwendungsspezifischer Name" index=24 id=V_ApplicationSpecificName

data type: 32-octet String UTF-8
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Prozessdaten Eingang" index=40 id=V_ProcessDataIn

data type: see ProcessDataIn!
access rights: ro
dynamic

Variable "Empfindlichkeit" index=80 id=V_Sensitivity

data type: 16-bit UInteger
allowed values: 16..255
default value: 255
access rights: rw

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "Schaltsignalhysterese" index=81 id=V_Hysteresis

data type: 8-bit UInteger
allowed values: 0 = normal, 1 = hoch
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Funktionsreserveschwelle" index=85 id=V_StabilityCntrl

data type: 8-bit UInteger
allowed values: 0 = Funktionsreserve 1.5, 1 = Funktionsreserve 2.0, 2 = Funktionsreserve 2.5, 3 = Funktionsreserve 3.0
default value: 1
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Signal Reserve" index=88 id=V_SignalReserve

data type: 8-bit UInteger
allowed values: 255 = exzellent, 0..100
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Konfiguration Ausgang" index=112 id=V_OMC

data type: 40-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 8-bit UInteger 0 = Nicht invertiert, 1 = Invertiert 0 Schaltsignal 1 Polarität
2 24 8-bit UInteger 0 = Nicht invertiert, 1 = Invertiert 0 Funktionsreserve Polarität
3 16 8-bit UInteger 0 = Inaktiv, 1 = Antivalent, 2 = Funktionsreserve Alarm 0 Ausgangsfunktion Q2
4 8 8-bit UInteger 0 = Gegentakt, 1 = N-schaltend, 2 = P-schaltend Ausgangsmodus Q1
5 0 8-bit UInteger 0 = Gegentakt, 1 = N-schaltend, 2 = P-schaltend Ausgangsmodus Q2

octet 0 1 2 3 4  
bit offset 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 2 3 4 5  
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0  

Variable "Lokale Bedienung" index=113 id=V_LOC

data type: 8-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Entsperrt, true = Gesperrt false Lokale Bedienelemente
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 1

Variable "Sensortestbetrieb" index=114 id=V_SOC

data type: 8-bit UInteger
allowed values: 0 = Normalbetrieb, 1 = Test - Sender aus
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Event Konfiguration" index=116 id=V_EVC

data type: 8-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 2-bit UInteger 0 = Kein Event, 3 = Event Warnung 0 Funktionsreserve Alarm
2 2 Boolean false = Kein Event, true = Event Meldung false Parameter verändert
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 2 1
element bit             1 0

Variable "Anzeigeelement Konfiguration" index=127 id=V_LIC

data type: 8-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Normale Anzeige, true = Lokalisierungsanzeige false Anzeigeeinstellung
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 1

Variable "Anwenderkennung 1" index=192 id=V_UT1

data type: 32-bit UInteger
default value: 0
access rights: rw

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Anwenderkennung 2" index=193 id=V_UT2

data type: 16-bit UInteger
default value: 0
access rights: rw

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "Betriebsstunden" index=224 id=V_OperHour

data type: 32-bit UInteger
default value: 0
access rights: ro
dynamic

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Temperatur Anzeige" index=225 id=V_TempInd

data type: 8-bit UInteger
allowed values: 0 = Normale Betriebstemperatur, 1 = Kritische Umgebungstemperatur, 2 = Übertemperatur
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Betriebsmonitor" index=226 id=V_OperMon

data type: 64-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit UInteger Betriebsstunden Übertemperatur
2 16 16-bit UInteger Übertemperaturzähler
3 8 8-bit Integer Maximale Betriebstemperatur
4 0 8-bit Integer Aktuelle Temperatur

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 3 4
element bit 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0 7 - 0 7 - 0

Events

CodeTypeNameDescription
25424 (0x6350)MessageParameteränderungLokale Bedienung: Parameter wurden verändert
36000 (0x8ca0)WarningFunktionsreserve AlarmFunktionsreserve unterschritten

Observer Menus

Identification Menu
Identifikation
Geräteinformation
V_VendorName, ro
V_ProductName, ro
V_ProductText, ro
V_ProductID, ro
V_SerialNumber, ro
Anwenderspezifische Information
V_ApplicationSpecificName, ro
V_UT1, ro
V_UT2, ro

Observation Menu
Beobachtung
V_ProcessDataIn, ro
V_SignalReserve * 0.1 + 0, ro Dec

Maintenance Menus

Identification Menu
Identifikation
Geräteinformation
V_VendorName, ro
V_ProductName, ro
V_ProductText, ro
V_ProductID, ro
V_SerialNumber, ro
Anwenderspezifische Information
V_ApplicationSpecificName, rw
V_UT1, rw
V_UT2, rw
Versionsinformation
V_HardwareRevision, ro
V_FirmwareRevision, ro

Parameter Menu
Parameter
Betriebsparameter
V_Sensitivity, rw
Betriebsartkonfiguration
V_Hysteresis, rw
V_OMC.Schaltsignal 1 Polarität, rw
V_StabilityCntrl, rw
V_OMC.Funktionsreserve Polarität, rw
Eventkonfiguration
V_EVC.Funktionsreserve Alarm, rw
V_EVC.Parameter verändert, rw
Ausgangskonfiguration
V_OMC.Ausgangsfunktion Q2, rw
Bedienelementekonfiguration
V_LOC.Lokale Bedienelemente, rw

Observation Menu
Beobachtung
Beobachtung
V_ProcessDataIn, ro
V_SignalReserve * 0.1 + 0, ro Dec

Diagnosis Menu
Diagnose
Servicefunktion
V_SOC, rw
V_LIC.Anzeigeeinstellung, rw
Betriebsinformation
V_OperHour * 1 + 0 h, ro Dec
V_TempInd, ro

Specialist Menus

Identification Menu
Identifikation
Geräteinformation
V_VendorName, ro
V_ProductName, ro
V_ProductText, ro
V_ProductID, ro
V_SerialNumber, ro
Anwenderspezifische Information
V_ApplicationSpecificName, rw
V_UT1, rw
V_UT2, rw
Versionsinformation
V_HardwareRevision, ro
V_FirmwareRevision, ro

Parameter Menu
Parameter
Betriebsparameter
V_Sensitivity, rw
Betriebsartkonfiguration
V_Hysteresis, rw
V_OMC.Schaltsignal 1 Polarität, rw
V_StabilityCntrl, rw
V_OMC.Funktionsreserve Polarität, rw
Eventkonfiguration
V_EVC.Funktionsreserve Alarm, rw
V_EVC.Parameter verändert, rw
Ausgangskonfiguration
V_OMC.Ausgangsfunktion Q2, rw
Bedienelementekonfiguration
V_LOC.Lokale Bedienelemente, rw

Observation Menu
Beobachtung
Beobachtung
V_ProcessDataIn, ro
V_SignalReserve * 0.1 + 0, ro Dec

Diagnosis Menu
Diagnose
Servicefunktion
V_SOC, rw
V_LIC.Anzeigeeinstellung, rw
V_SystemCommand, wo Button:=130
Betriebsinformation
V_OperHour * 1 + 0 h, ro Dec
V_TempInd, ro
Kommunikationseigenschaften
V_DirectParameters_1.Minimale Zykluszeit, MinCycleTime
V_DirectParameters_1.Master Zykluszeit, MasterCycleTime
V_DirectParameters_1.IO-Link Versions-ID, Hex

Note: This page shows the content of an IODD file transformed into HTML format. In the case of disparity between this and the XML view, the content of the XML file takes precedence.
Created by IODD Viewer V1.1.