For detailed data and product description refer to the data sheets at
Proximity Sensors,
Inductive Sensors,
slot types
1
.1.3
Technical Data
Electrical Connection
H
W
L
lc
G
General Data
Slot width
2
mm
Depth of immersion (lateral)
5 ... 7
typ. 6 mm
Type of voltage
DC
Nominal voltage
8
V
Switching frequency
0 ... 5000
Hz
Suitable for 2:1 technology
,
with reverse polarity protection diode
Housing material
PBT
Protection degree
IP67
Connection type
flexible leads LIFYW , 500 mm
Model Number
SJ2-SN
SJ2-S1N
Switching element function
NAMUR, NO
NAMUR, NC
Current consumption
Measuring plate not detected
3
mA
1
mA
Measuring plate detected
3
mA
1
mA
Ambient temperature
-25 ... 100
°C (-13 ... 212 °F)
-40 ... 100
°C (-40 ... 212 °F)
Use in the Hazardous Area
Use in the hazardous area
see instruction manuals
Category
1
G; 2G; 3G; 1D
Approvals and Certificates
Control drawing
116-0165
F
UL approval
cULus Listed, General Purpose
CSA approval
cCSAus Listed, General Purpose
CCC approval
Products with a maximum operating voltage of
36
V do not bear a CCC
marking because they do not require approval.
Dimensions
Length L [mm]
15
Width W [mm]
8
Height H [mm]
12
Slot width G [mm]
2
Connector area l
c
[
mm]
0
Inductive slot sensor
2
mm slot width (NAMUR with safety function)
2
mm slot width
Extrardinary fast response
DC, 2-wire NAMUR
Flexible leads version
EX approval 1G/1D for use up to
zone 0 / zone 20
Applicable up to SIL3 acc. to IEC
61508
Properties
Your Benefit
RD
L+
L-
GN
BN
L+
L-
BU
SJ2-S1N
SJ2-SN
0102