600
Ultrasonic Sensors
3
Ultrasonic Sensors,
Thru-Beam Sensors,
cylindrical
3
.2
Ultrasonic Sensors,
Diffuse Mode Sensors,
cylindrical
3
.1
Ultrasonic Sensors,
Thru-Beam Sensors,
rectangular types
3
.2
Ultrasonic Sensors,
Diffuse Mode Sensors,
rectangular types
3
.1
Ultrasonic Sensors,
Sensors for Separate Evaluation
3
.3
Ultrasonic Sensors,
Double Sheet Sensors
3
.4
Ultraschallsensoren,
Ultrasonic Sensor Accessories
3
.5
Germany: +49 621 776-4411
Consider the General Notes on the Information in the Pepperl+Fuchs Product Catalogs
Pepperl+Fuchs Group
fa-info@de.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
Copyright Pepperl+Fuchs
Connection Elements
A2
4-
wire, DC, PNP, antivalent
E01
4-
wire,
NO/NC
NPN
(
independently adjustable)
E23
4-
wire,
NO/NC
PNP
(
independently adjustable)
E2
3-
wire, DC, PNP, NO
E4
3-
wire, DC, NPN,
NO/NC
E5
3-
wire, DC, PNP,
NO/NC
E6
4-
wire,
NO/NC
PNP
(
independently adjustable)
E7
4-
wire,
NO/NC
NPN
(
independently adjustable)
E8
4-
wire, DC, PNP, dual, NO
E9
4-
wire, DC, PNP, dual, NC
I
Analog current output
U
Analog voltage output
UK
AC/DC with relay output
2
K
2
relay outputs
3
K
3
relay outputs
F
Frequency output
PWM
Pulse width modulating output
BIT
Serial digital output
There are many possible combinations.
Connection Elements
-
Sensor with cable connection or terminal compartment
V1
M12 x 1 device connector for DC proximity switches, 4-pole
V15
M12 x 1 device connector for DC proximity switches, 5-pole
V17
M12 x 1 device connector for DC proximity switches, 8-pole
V31
M8 device connector for DC proximity switches, 4-pole
(
suitable for snap closure)
V95
7/8’’ - 16
UN device connector for AC/DC proximity
switches, 5-pole
V7
connector for AC/DC proximity switches, 7-pole
U C 1000 - 18 G M 90 - E2
-
V1
A
-
IO
Cylindrical
usable
threaded length (mm)
U
Ultrasonic sensors
B
Basis line
BE
Basis line, through beam barrier
BEC
Basis line, through beam barrier, resistant to chemicals
BH
Basis line for height monitoring
C
Comfort line
CE
Comfort line, through beam barrier
CC
Comfort line, resistant to chemicals
MC
Comfort line with metal transducer
ME
Through beam barrier with metal transducer
DB
Double sheet monitor, Basis line
DC
Double sheet monitor, Comfort line
LB
Double sheet monitor for label identification
GB
Double sheet monitor for splice detection
Measurement range
60
mm ... 10 m
Diameter in mm
Rectangular type
F12, F42, F43, F54, F65, F77, F260
L2 VariKont L
®
U VariKont
®
FP Surface switch
M
Metal (brass, nickel plated)
H
Stainless steel
1.4435/
AlSI 316L
S
Stainless steel
1.4305/
AISI 303
-
Smooth housing
G
Threading
Option 1
A
right angled transducer
S
rotable transducer
Option 2
K
separate transducer
IO
Sensor with IO-Link
R/R2
RS 232 Interface
FA
Hygienic design, EHEDG
(
product contact area)
FB
Hygienic design
(
splash area)
Type Code, Ultrasonic Sensors
Ultrasonic Sensors
Introduction