951
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
Logic Control Units,
Counters and Timers
9
.1
Technical Data
For detailed data and product description refer to the data sheets at
Electrical Connection
General Data
Function
Counter
Timer
Tachometer
Display value
digit height 9 mm
Reset
manual or external
Sensor supply
Storage temperature
-25 ... 75 °C (-13 ... 167 °F)
Relative humidity
93 % at 40 °C (noncondensing)
Dimensions
48 mm x 48 mm x 109.8 mm
Model Number
KC-LCD-48-1R-24VDC
KC-LCDL-48-2R-24VDC
KC-LCDC-48-2T-24VDC
KC-LCDC-48-2R-24VDC
KC-LCDC-48-6T-24VDC
Type
2-line, 2 x 6-digit LC display with sign
2-line, 2 x 6-digit LC display with sign
backlighted
2-line, 2 x 6-digit LC display with sign
Multicolor, backlit
● ● ●
Operating voltage
10 ... 30 V
DC
● ● ● ●
11 ... 30 V
DC
Power consumption
max. 1.5 W
● ● ● ●
max. 4 W
Counting frequency
max. 50 kHz
30 Hz / 5 kHz
30 Hz / 55 kHz
● ● ●
Output type
1 relay output
2 relay outputs
2 transistor switching outputs
6 transistor switching outputs
Ambient temperature
-10 ... 50 °C (14 ... 122 °F)
-20 ... 65 °C (-4 ... 149 °F)
● ● ● ●
LCD-batch controller
LCD batch controller with 1 pre-
selection
10 - 30 V
DC
supply voltage
2 x 6 digits
Adding/subtracting via 2 separate
inputs
Easy-to-read, 2-line LCD display
with symbols for indicated pre-
selection and output status
PNP and NPN sensors can be
connected
Properties
Benefits
Signal and control inputs
1
Sensor supply voltage
2
GND (0V)
3
INP A (Signal input A)
4
INP B (Signal input B)
5
RESET (Reset input)
6
LOCK (Input Keypad lock)
7
GATE (Gate input)
8
MPI (User input)
Supply voltage and outputs
9
Relay contact C.
10
Relay contact N.O.
11
Relay contact C.
12
Relay contact N.O.
13
Relay contact N.C.
14
10 ...30 V DC
15
GND (0V)
Output 2
Supply
voltage
Output 1
Signal and control inputs
1
Sensor supply voltage
2
GND (0V)
3
INP A (Signal input A)
4
INP B (Signal input B)
5
RESET (Reset input)
6
LOCK (Input Keypad lock)
7
GATE (Gate input)
8
MPI (User input)
Supply voltage and outputs
9
Collector
10
Emitter
11
Collector
12
not connected
13
Emitter
14
10 ... 30 V DC
15
GND (0V)
Output 2
Supply
voltage
Output 1
KC-LCDL-48-2R-24VDC
KC-LCDC-48-2R-24VDC
KC-LCDC-48-2T-24VDC