958
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
Logic Control Units,
Digital Meters
9
.2
Technical Data
For detailed data and product description refer to the data sheets at
Electrical Connection
General Data
Data storage
10
6
storage cycles or 10 years, EEPROM
Programming
keypad-driven menu
Type
5-digit 7-segment LED display, red
Display value
digit height 14.2 mm
Display range
-19999 ... 99999
with suppression of leading zeros
Output type
2 Relay changeover outputs
Input type
Input 1
Measurement input for thermoelements B, E, J, K, N, R, S, T
Input 2
Measurement input for resistance thermometer type Pt100, Pt1000
Input 3
Measurement input for resistance measurement
Sensor supply
Ambient temperature
-20 ... 65 °C (-4 ... 149 °F)
Storage temperature
-40 ... 85 °C (-40 ... 185 °F)
Relative humidity
75 % (noncondensing)
Dimensions
96 mm x 48 mm x 90.7 mm
Protection degree
IP65 (front)
Model Number
KT-LED-96-2R-24VDC
KT-LED-96-2R-230VAC
Operating voltage
10 ... 30 V
DC
galvanically isolated
90 ... 260 V
AC
Power consumption
max. 2 W
max. 6 VA
Suitable Sensors
Pt100/Ni100 resistance thermometer, with sensor
breakage monitoring
Thermocouple J, K, N, with sensor breakage monitoring
Temperature control unit with LED display
LED display
Temperature control unit
10 - 30 V
DC
and 90 - 260 V
AC
supply
voltage version
5 digits
Properties
Electrical connection X2
Thermocouples
Resistance thermometer
Pt100/Pt1000
Control inputs and
auxiliary power (Vout)
4-wire
3-wire
2-wire
Voltage measurement
* Alternatively connect directly to DC power supply
(galvanic isolation of control and measurement inputs
+ -
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9 10 11
ϑ
ϑ
ϑ
1 2 3 4 5 6 7 8 9 10 11
1 2 3 4 5 6 7 8 9 10 11
+ -
*
*
*
10 11
Relayoutput
Wire assignment
Pin
Function
Thermocouples
1
Positive sensing arm
2
Negative sensing arm
Resistance thermometer
1
Pt100 or 0 ... 400
Ω
2
Pt1000 or 0 ... 4000
Ω
Voltage measurement
1
Voltage input (V)
2
GND 1 (analog)
Control inputs and auxiliary power (Vout)
6
Keypad lock-out “Key”
7
GND2 Key/MPI
8
MP-input “Reset-alarm-latch/
Display-Hold”
9
GND3 (for Vout)
10
Vout + 10 V/30 mA
11
n.c.
Pin
Function
Power supply and alarm outputs
7
+ 10 ... 30 V DC
8
GND4 (0 V DC)
X1:
X2:
1 2 3 4 5 6 7 8
OUT2 OUT1
1 2 3
91011
4 5 6 7 8
X2
1 2 3 4 5 6 7 8
X1
KT-LED-96-2R-230VAC
KT-LED-96-2R-24VDC
KT-LED-96-2R-24VDC
1...,950,951,952,953,954,955,956,957,958,959 961,962,963,964,965,966,967,968,969,970,...1124