324
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
Proximity Sensors,
Inductive Sensors,
slot type
1
.1.3
Technical Data
For detailed data and product description refer to the data sheets at
Electrical Connection
H
L
W
G
lc
General Data
Output type
NAMUR, NC
Nominal voltage
8.2 V (R
i
approx. 1 k
)
Operating voltage
5 ... 25 V
Current consumption
Measuring plate not detected
3 mA
Measuring plate detected
1 mA
Protection degree
IP67
Connection type
cable PVC , 2 m
Model Number
SJ10-N
SJ15-N
SJ30-N
Slot width
10 mm
●
15 mm
●
30 mm
●
Lateral immersion switchpoint
13.5 ... 16.5 mm , typ. 15 mm
●
16 ... 19 mm , typ. 17.5 mm
●
27 ... 30 mm
●
Switching frequency
0 ... 1000 Hz
●
●
0 ... 150 Hz
●
Ambient temperature
-25 ... 100 °C (-13 ... 212 °F)
●
-25 ... 70 °C (-13 ... 158 °F)
●
●
Housing material
ABS
●
PBT
●
●
Use in the Hazardous Area
Use in the hazardous area
see instruction manuals
●
●
●
Category
1G; 2G; 1D
●
●
●
Approvals and Certificates
FM control drawing
116-0165F
●
●
●
UL approval
cULus Listed, General Purpose
●
●
●
CSA approval
cCSAus Listed, General Purpose
●
●
●
CCC approval
CCC approval / marking not required for sensors rated
36 V
Dimensions
Length L [mm]
25
30
51
Width W [mm]
44
48
84
Height H [mm]
45
60
110
Slot width G [mm]
10
15
30
Connector length l
c
[mm]
6
0
35
KCD2-SR-Ex2
2-channel isolated amplifier
For detailed information on isolated amplifiers refer to the data sheets at
These and more accessories can be found in chapter 10
See pages from 970 ... for cordsets See pages 1066 ... for mounting accessories
Accessories
Inductive slot sensor
10 / 15 / 30 mm slot width (NAMUR)
Application Note:
Reference appendix, data sheet,
operating instructions, and appropriate standards.
To be used within the electrical, environmental, and
mechanical limitations of the device and area.
Up to 30 mm slot width
Fast response
NAMUR output
Cable version
ATEX approval up to zone 0 / zone
20
Intrinsically safe when connected
to approved device
FM Class/Div approvals
Properties
Benefits
BN
L+
L-
BU
SJ10-N
SJ15-N
SJ30-N
0102