329
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
Proximity Sensors,
Inductive Sensors,
ring type
1
.1.4
Technical Data
For detailed data and product description refer to the data sheets at
Electrical Connection
L
W
D
H
lc
General Data
Output type
NAMUR, NC
Type of voltage
DC
Nominal voltage
8.2 V (R
i
approx. 1 k
)
Measuring cylinder (target)
9S20K
Current consumption
Measuring plate not detected
3 mA
Measuring plate detected
1 mA
Ambient temperature
-20 ... 65 °C (-4 ... 149 °F)
Housing material
PBT
Protection degree
IP67
Connection type
cable PVC , 2 m
Model Number
RC10-14-N0
RC15-14-N0
Inside diameter
10 mm
15 mm
Measuring cylinder (target)
min. diameter / min. length 2.5 mm / 4 mm
3 mm / 4 mm
Switching frequency
0 ... 1500 Hz
0 ... 2000 Hz
Suitable for 2:1 technology
yes , Reverse polarity protection
diode not required
Use in the Hazardous Area
Use in the hazardous area
see instruction manuals
Category
2G
Approvals and Certificates
FM control drawing
116-0165F
UL approval
cULus Listed, General Purpose
CSA approval
cCSAus Listed, General Purpose
Dimensions
Length L [mm]
20
Width W [mm]
25
Height H [mm]
32.5
Inside diameter D [mm]
10
15
Connector length l
c
[mm]
0
KCD2-SR-Ex2
2-channel isolated amplifier
KFD2-SRA-Ex4
4-channel isolated amplifier for 2:1 technology
For detailed information on isolated amplifiers refer to the data sheets at
These and more accessories can be found in chapter 10
See pages from 970 ... for cordsets See pages 1066 ... for mounting accessories
Accessories
Inductive ring sensor
10 mm / 15 mm inside diameter (NAMUR)
Application Note:
Reference appendix, data sheet,
operating instructions, and appropriate standards.
To be used within the electrical, environmental, and
mechanical limitations of the device and area.
Ø10 mm and Ø15 mm inside
diameters
9S20K targets
Very fast response
NAMUR output
EX approved sensor applicable up
to zone 1
Intrinsically safe when connected
to approved device
FM Class & Division approvals
Properties
Benefits
BN
L+
L-
BU
RC10-14-N0
RC15-14-N0
0102