876
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
AS-Interface,
Safety at Work
7
.3
Technical Data
For detailed data and product description refer to the data sheets at
W
H
L
General Data
AS-Interface specification
V3.0
Duplicate address detection from AS-Interface slaves
Earth fault detection
integrated
EMC monitoring
integrated
Switch-on delay
< 10 s
Safety Integrity Level (SIL)
SIL 3
Performance level (PL)
PL e
MTTF
d
200 a
B
10d
2 E+7
Display
Illuminated graphical LC display for addressing and error messages
noitarugifnoc erotS
drac pihC
Diagnostic Interface
RS 232, serial
Inputs
Number/Type
4 EDM/Start inputs
Outputs
Safety output
2 potential-free contacts,
2 PNP transistor outputs
Ambient temperature
0 ... 55 °C (32 ... 131 °F)
Protection degree
IP20
Model Number
VBG-PB-K30-DMD-S16
VBG-PB-K30-D-S16
VBG-PBS-K30-DMD
VBG-PN-K30-DMD-S16
VBG-PNS-K30-DMD
VBG-ENX-K30-DMD-S16
AS-Interface networks
1
2
Response delay
< 40 ms
UL File Number
E223772
Upper level network
Interface type
2 x RJ-45
Sub-D
Protocol
Ethernet/IP + MODBUS TCP/IP
PROFIBUS
PROFINET
PROFISAFE
Dimensions
Length L [mm]
89
Width W [mm]
100
110
Height H [mm]
120
USB-0,8M-PVC ABG-SUBD9
Interface converter USB/RS 232
VAZ-SW-SIMON+
Software for configuration of K30 Master Monitors/K31 Safety Monitors
VAZ-PB-DB9-W
PROFIBUS Sub-D Connector with switchable terminal resistance
These and more accessories can be found in chapter 7.6 from page 905
See pages from 970 ... for cordsets
See pages 1066 ... for mounting accessories
Accessories
AS-Interface Safety Monitor
PROFIBUS, PROFINET and
Ethernet/IP versions
Versions for 1 and 2 AS-Interface
masters
4 safe OSSD
SIL 3 / Ple
A single safety configuration
processes safe data from two
AS-Interface networks
Chip card makes device
replacement fast and easy
Sharing of safe data between
several gateway/safety controllers
enables safety systems with nearly
1000 safe devices
VBG-PBS-K30-DMD & VBG-PNS-K30-DMD
PROFISAFE gateway brings AS-
Interface simplicity to PROFISAFE
enabled PLC
Properties
Benefits
R