227
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
Proximity Sensors,
Inductive Sensors,
cylindrical
1
.1.1
Technical Data
For detailed data and product description refer to the data sheets at
Electrical Connection
D
L
Pos. A
Pos. B
Pos. C
lc
l1
lt
General Data
Output type
NAMUR, NC
Nominal voltage
8.2 V (R
i
approx. 1 k
)
Ambient temperature
-25 ... 100 °C (-13 ... 212 °F)
Housing material
Stainless steel 1.4305 / AISI 303
Model Number
NJ2-12GM-N
NJ4-12GM-N
NCB2-12GM35-N0
NCB4-12GM40-N0
NCN4-12GM35-N0
NJ2-12GM-N-V1
NJ4-12GM-N-V1
NCB2-12GM35-N0-V1
NCB4-12GM40-N0-V1
NCN4-12GM35-N0-V1
Rated operating distance
2 mm
● ●
● ●
4 mm
● ● ● ● ● ●
Installation
flush
● ● ● ● ● ●
non-flush
● ●
Current consumption
Measuring plate not detected
2.2 mA
● ●
3 mA
● ● ● ● ● ●
Measuring plate detected
1 mA
● ● ● ● ● ● ● ● ● ●
Switching frequency
0 ... 1000 Hz
0 ... 1500 Hz
● ●
● ●
0 ... 2000 Hz
0 ... 800 Hz
Suitable for 2:1 technology
, Reverse polarity protection
diode not required
● ● ● ● ● ●
Switching state indication
LED, yellow
● ● ●
● ● ●
Protection degree
IP66 / IP67
● ●
IP67
● ● ● ● ● ● ●
Connection type
Connector M12 x 1 , 4-pin
● ● ● ● ●
cable PVC , 2 m
● ● ● ● ●
Use in the Hazardous Area
Use in the hazardous area
see instruction manuals
● ● ● ● ● ● ● ● ● ●
Category
1G; 2G
● ●
1G; 2G; 1D
● ●
● ●
1G; 2G; 3G
1G; 2G; 3G; 1D; 3D
● ●
1G; 2G; 3G; 3D
Approvals and Certificates
FM control drawing
116-0165F
● ● ● ● ● ● ● ● ● ●
UL approval
cULus Listed, General Purpose
● ● ● ● ● ● ● ● ● ●
CSA approval
cCSAus Listed, General Purpose
● ● ● ● ● ● ● ● ● ●
CCC approval
CCC approval / marking not required for sensors rated
36 V
Dimensions
Length L [mm]
35 33 35 40 35 50 50 50 55 50
Diameter D [mm]
M12 x 1
Thread length l
t
[mm]
35 28 32 37 27 50 45 34 40 29
Cap length l
1
[mm]
0 5 0 0 5 0 5 0 0 5
Connector length l
c
[mm]
0
6
LED position
-
Pos. C -
Pos. B
AB-12
Right angled mounting bracket
V1-G-N-2M-PUR
Female cordset, M12, 2-pin, NAMUR, PUR cable, straight
V1-W-N-2M-PUR
Female cordset, M12, 2-pin, NAMUR, PUR cable, angled
KCD2-SR-Ex2
2-channel isolated amplifier
For detailed information on isolated amplifiers refer to the data sheets at
These and more accessories can be found in chapter 10
See pages from 970 ... for cordsets See pages 1066 ... for mounting accessories
Accessories
Inductive sensor
cylindrical, Ø 12 mm (NAMUR)
Application Note:
Reference appendix, data sheet,
operating instructions, and appropriate standards.
To be used within the electrical, environmental, and
mechanical limitations of the device and area.
Ø12 mm housing
2 mm and 4mm sensing ranges
NAMUR output
Cable and connector versions
ATEX approved sensor applicable
up to zone 0 and zone 20
Intrinsically safe when connected
to approved device
FM Class and Division approvals
Properties
Benefits
1
L+
L-
2
BN
L+
L-
BU
NCB2-12GM35-N0-V1
NJ2-12GM-N-V1
NCB4-12GM40-N0-V1
NCN4-12GM35-N0-V1
NJ4-12GM-N-V1
NCB2-12GM35-N0
NJ2-12GM-N
NCB4-12GM40-N0
NCN4-12GM35-N0
NJ4-12GM-N
1
3
4
2
1
BN
2
BU
Wire colors in accordance with EN 60947-5-6
(brown)
(blue)
0102
1...,219,220,221,222,223,224,225,226,227,228 230,231,232,233,234,235,236,237,238,239,...1124