229
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
Proximity Sensors,
Inductive Sensors,
cylindrical
1
.1.1
Technical Data
For detailed data and product description refer to the data sheets at
Electrical Connection
D
L
Pos. A
Pos. B
Pos. C
lc
l1
lt
General Data
Output type
NAMUR, NC
Nominal voltage
8.2 V (R
i
approx. 1 k
)
Ambient temperature
-25 ... 100 °C (-13 ... 212 °F)
Housing material
Stainless steel 1.4305 / AISI 303
Model Number
NJ5-18GM-N
NJ8-18GM-N
NCB5-18GM40-N0
NCB8-18GM40-N0
NCN8-18GM40-N0
NJ5-18GM-N-V1
NJ8-18GM-N-V1
NCB5-18GM40-N0-V1
NCB8-18GM40-N0-V1
NCN8-18GM40-N0-V1
Rated operating distance
5 mm
● ●
● ●
8 mm
● ● ● ● ● ●
Installation
flush
● ● ● ● ● ●
non-flush
● ●
Current consumption
Measuring plate detected
1 mA
● ● ● ● ● ● ● ● ● ●
Measuring plate not detected
2.2 mA
3 mA
● ● ● ● ● ● ● ●
Switching frequency
0 ... 200 Hz
0 ... 300 Hz
0 ... 400 Hz
0 ... 500 Hz
0 ... 1500 Hz
Suitable for 2:1 technology
, Reverse polarity protection
diode not required
Switching state indication
LED, yellow
● ● ●
Protection degree
IP66 / IP67
● ●
IP67
● ●
● ● ● ● ● ●
Connection type
Connector M12 x 1 , 4-pin
● ● ● ● ●
cable PVC , 2 m
● ● ● ● ●
Use in the Hazardous Area
Use in the hazardous area
see instruction manuals
● ● ● ● ● ● ● ● ● ●
Category
1G; 2G
● ●
1G; 2G; 1D
● ●
● ●
1G; 2G; 3G
1G; 2G; 3G; 1D; 3D
● ●
1G; 2G; 3G; 3D
Approvals and Certificates
FM control drawing
116-0165F
● ● ● ● ● ● ● ● ● ●
UL approval
cULus Listed, General
Purpose
● ● ● ● ● ● ● ● ● ●
CSA approval
cCSAus Listed, General
Purpose
● ● ● ● ● ● ● ● ● ●
CCC approval
CCC approval / marking not required for sensors rated
36 V
Dimensions
Length L [mm]
40
40
50
55
Diameter D [mm]
M18 x 1
Thread length l
t
[mm]
40 24 37 37 27 40 24 40 40 30
Cap length l
1
[mm]
0 16 0 10 0 16 0 10
Connector length l
c
[mm]
0
10
15
LED position
Pos.
-
C
-
C
Inductive sensor
cylindrical, Ø 18 mm (NAMUR)
Application Note:
Reference appendix, data sheet,
operating instructions, and appropriate standards.
To be used within the electrical, environmental, and
mechanical limitations of the device and area.
Ø18 mm housing
5 mm and 8 mm sensing ranges
NAMUR output
Cable and connector versions
ATEX approved sensor applicable
up to zone 0 and zone 20
Intrinsically safe when connected
to approved device
FM Class and Division approvals
Properties
Benefits
1
L+
L-
2
BN
L+
L-
BU
NCB5-18GM40-N0
NJ5-18GM-N
NCB8-18GM40-N0
NCN8-18GM40-N0
NJ8-18GM-N
NCB5-18GM40-N0-V1
NJ5-18GM-N-V1
NCB8-18GM40-N0-V1
NCN8-18GM40-N0-V1
NJ8-18GM-N-V1
1
3
4
2
1
BN
2
BU
Wire colors in accordance with EN 60947-5-6
(brown)
(blue)
0102