309
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
Proximity Sensors,
Inductive Sensors,
rectangular types
1
.1.2
Technical Data
For detailed data and product description refer to the data sheets at
Electrical Connection
0102
Application Note:
Reference appendix, data sheet,
operating instructions, and appropriate standards.
To be used within the electrical, environmental, and
mechanical limitations of the device and area.
Limit switch style housing
40 mm, non-flush mountable
NAMUR output
Terminal compartment
ATEX approval up to zone 1
Intrinsically safe when connected
to approved device
FM Class/Div approvals
Properties
Benefits
Wh
L
H
lc
W
General Data
Rated operating distance
40 mm
Installation
non-flush
Output type
NAMUR, NC
Type of voltage
DC
Nominal voltage
8.2 V (R
i
approx. 1 k
)
Current consumption
Measuring plate not detected
3 mA
Measuring plate detected
1 mA
Switching frequency
0 ... 100 Hz
Ambient temperature
-25 ... 100 °C (-13 ... 212 °F)
Protection degree
IP68
Connection type
screw terminals
Model Number
NJ40+U2+N
NJ40+U4+N
Material
PBT housing/plastic base
PBT housing/metal base
Use in the Hazardous Area
Use in the hazardous area
see instruction manuals
Category
2G
Approvals and Certificates
FM Control drawing
116-0165F
UL approval
cULus Listed, General Purpose
CSA approval
cCSAus Listed, General Purpose
CCC approval
CCC approval / marking not required for sensors rated
36 V
Dimensions
Length L [mm]
118
Width W [mm]
40
Height H [mm]
40
Head width W
h
[mm]
55
Head height H
h
[mm]
55
Connector length l
c
[mm]
0
Connector thread
conduit entrance with
1/2" NPT opening
MHW 01
Modular mounting bracket
KCD2-SR-Ex2
2-channel isolated amplifier
For detailed information on isolated amplifiers refer to the data sheets at
These and more accessories can be found in chapter 10
See pages from 970 ... for cordsets See pages 1066 ... for mounting accessories
Accessories
1
L+
L-
2
NJ40+U4+N
NJ40+U2+N
Inductive sensor
Limit switch style (NAMUR)
1...,301,302,303,304,305,306,307,308,309,310 312,313,314,315,316,317,318,319,320,321,...1124