313
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
Proximity Sensors,
Inductive Sensors,
rectangular types
1
.1.2
Technical Data
For detailed data and product description refer to the data sheets at
Electrical Connection
W
L
H
lc
Danger!
In safety-related applications the sensor must be operated with a qualified fail safe interface from
Pepperl+Fuchs, such as KFD2-SH-EX1.
Consider the "exida Functional Safety Assessment" document which is available on
as an integral part of this product’s documentation.
Application Note:
Reference appendix, data sheet, operating instructions, and appropriate standards.
To be used within the electrical, environmental, and mechanical limitations of the device and area.
Model Number
NJ40-FP-SN-P4
Rated operating distance
40 mm
Installation
non-flush
Output type
NAMUR, NC
Type of voltage
DC
Nominal voltage
8.2 V (R
i
approx. 1 k
)
Current consumption
Measuring plate not detected
3 mA
Measuring plate detected
1 mA
Switching frequency
0 ... 100 Hz
Ambient temperature
-40 ... 100 °C (-40 ... 212 °F)
Housing material
PBT housing / metal base
Protection degree
IP68
Connection type
screw terminals
Use in the Hazardous Area
Use in the hazardous area
see instruction manuals
Category
2G; 1D
Approvals and Certificates
Control drawing
116-0165F
UL approval
cULus Listed, General Purpose
CSA approval
cCSAus Listed, General Purpose
CCC approval
CCC approval / marking not required for sensors rated
36 V
Dimensions
Length L [mm]
80
Width W [mm]
80
Height H [mm]
40
Connector length l
c
[mm]
11 ( M20 x 1.5 )
KFD2-SH-EX1
Isolated amplifier
These and more accessories can be found in chapter 10
See pages from 970 ... for cordsets See pages 1066 ... for mounting accessories
Accessories
Inductive sensor
FP series (NAMUR with safety function)
Flat pack housing
40 mm, non-flush mountable
NAMUR output
Terminal compartment
Usable up to SIL 3 acc. to IEC 61508
ATEX approval up to
zone 1 / zone 20
FM Class and Division approvals
Properties
Benefits
1
L+
L-
2
NJ40-FP-SN-P4
0102
1...,305,306,307,308,309,310,311,312,313,314 316,317,318,319,320,321,322,323,324,325,...1124