310
Germany: +49 621 776-4411
Refer to General Notes Relating to Product Information
Pepperl+Fuchs Group
USA: +1 330 486 0001
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
Proximity Sensors,
Inductive Sensors,
rectangular types
1
.1.2
Technical Data
For detailed data and product description refer to the data sheets at
Electrical Connection
0102
Application Note:
Reference appendix, data sheet,
operating instructions, and appropriate standards.
To be used within the electrical, environmental, and
mechanical limitations of the device and area.
Limit switch style housing
Up to 40 mm sensing ranges
NAMUR output
Terminal compartment and
connector versions
ATEX approval up to zone 0
Intrinsically safe when connected
to approved device
Properties
Benefits
Wh
L
H
lc
W
General Data
Output type
NAMUR, NC
Type of voltage
DC
Nominal voltage
8.2 V (R
i
approx. 1 k
)
Switching state indication
LED, yellow
Ambient temperature
-25 ... 100 °C (-13 ... 212 °F)
Protection degree
IP68 / IP69K
Model Number
NBB15-U2K-N0
NBB15-U4K-N0
NBB20-U1K-N0
NBB20-U4K-N0
NBN40-U1K-N0
NBN40-U2K-N0
NBN40-U4K-N0
NBB15-U4K-N0-V1
NBN40-U1K-N0-V1
NBN40-U4K-N0-V1
Rated operating distance
15 mm
● ●
20 mm
● ●
40 mm
● ● ● ● ●
Installation
flush
● ● ● ●
non-flush
● ● ● ● ●
Current consumption
Measuring plate not detected
2.2 mA
● ● ● ● ● ● ● ●
3 mA
● ●
Measuring plate detected
1 mA
● ● ● ● ● ● ● ● ● ●
Switching frequency
0 ... 100 Hz
0 ... 150 Hz
● ● ● ●
0 ... 250 Hz
0 ... 300 Hz
● ● ●
Material
Housing PA/base PA
● ● ● ●
Housing PA/base metal
● ●
● ● ●
Connection type
Connector M12 x 1 , 4-pin
● ● ●
screw terminals
● ● ● ● ● ● ●
Use in the Hazardous Area
Use in the hazardous area
see instruction manuals
● ● ● ● ● ● ● ● ● ●
Category
1G; 2G; 3G
● ● ● ● ● ● ● ● ● ●
Approvals and Certificates
UL approval
cULus Listed, General Purpose
● ● ● ● ● ● ● ● ● ●
CSA approval
cCSAus Listed, General Purpose
● ● ● ● ● ● ● ● ● ●
CCC approval
CCC approval / marking not required for sensors rated
36 V
Dimensions
Length L [mm]
118
Width W [mm]
40
Height H [mm]
40
Connector length l
c
[mm]
0
30
Connector thread
conduit entrance with
1/2" NPT opening
● ● ● ● ●
Connector thread
M20 x 1.5
● ●
MHW 01
Modular mounting bracket
1/2"NPT-V1-G-S-.3M
Receptacle
1/2"NPT to
M12 x 1, 4-pin
V1-G
4-pin, M12 female field-attachable connector
V1-W
4-pin, M12 female field-attachable connector
V1-G-N-2M-PUR
Female cordset, M12, 2-pin, NAMUR, PUR cable
V1-W-N-2M-PUR
Female cordset, M12, 2-pin, NAMUR, PUR cable
KCD2-SR-Ex2
2-channel isolated amplifier
For detailed information on isolated amplifiers refer to the data sheets at
These and more accessories can be found in chapter 10
See pages from 970 ... for cordsets See pages 1066 ... for mounting accessories
Accessories
1
L+
L-
2
1
L+
L-
2
NBB15-U2K-N0
NBB15-U4K-N0
NBB20-U1K-N0
NBN40-U1K-N0
NBB20-U4K-N0
NBN40-U4K-N0
NBN40-U2K-N0
NBB15-U4K-N0-V1
NBN40-U4K-N0-V1
NBN40-U1K-N0-V1
1
3
4
2
1
BN
2
BU
Wire colors in accordance with EN 60947-5-6
(brown)
(blue)
Inductive sensor
Limit switch style (NAMUR)